#1586 Resolves issue in P25 message framer where after transmitting the current message the mDataUnitId is set to null and this causes an NPE when subsequent code is executed prior to shutdown of the channel. (#1593)
Co-authored-by: Dennis Sheirer <dsheirer@github.com>
This commit is contained in:
@@ -322,17 +322,19 @@ public class P25P1MessageFramer implements Listener<Dibit>, IP25P1DataUnitDetect
|
||||
TSBKMessage tsbkMessage = TSBKMessageFactory.create(mChannelStatusProcessor.getDirection(),
|
||||
mDataUnitID, mBinaryMessage, mNAC, getTimestamp());
|
||||
|
||||
int messageLength = mDataUnitID.getMessageLength();
|
||||
|
||||
mMessageListener.receive(tsbkMessage);
|
||||
|
||||
if(tsbkMessage.isLastBlock())
|
||||
{
|
||||
reset(mDataUnitID.getMessageLength());
|
||||
reset(messageLength);
|
||||
mTrailingDibitsToSuppress = 1;
|
||||
}
|
||||
else
|
||||
{
|
||||
updateBitsProcessed(mDataUnitID.getMessageLength());
|
||||
mBinaryMessage = new CorrectedBinaryMessage(mDataUnitID.getMessageLength());
|
||||
updateBitsProcessed(messageLength);
|
||||
mBinaryMessage = new CorrectedBinaryMessage(messageLength);
|
||||
if(mDataUnitID == P25P1DataUnitID.TRUNKING_SIGNALING_BLOCK_1)
|
||||
{
|
||||
mDataUnitID = P25P1DataUnitID.TRUNKING_SIGNALING_BLOCK_2;
|
||||
|
||||