and auto-correction for R820T tuners.
-Updated TunerModel and TunerViewPanel to add 2 new columns to
display the current tuner's PPM setting and (when available) the
measured frequency error averaged over 5 second intervals provided by
certain decoders (e.g. P25 C4FM and LSM). Frequency error value from
P25 decoders is provided from the Costas Loop PLL once 2 or more P25
message sync events have been observed in a short period.
-Updated R820T tuner to auto-correct PPM when measured frequency error
exceeds the +/- 0.4PPM threshold for a period of 30 seconds or more.
Feature can be enabled/disabled by user in the tuner editor panel.
Resolved several issues with P25 C4FM/LSM decoders that was impacting
performance related to channel misalignment from tuner PPM offsets.
Adds capability to disable spectral display.
Adds right-click context
menu items to disable display and/or reenable display by selecting
another tuner.
Adds view menu items to disable spectral display or show a tuner.
Persists spectral display enabled state across application run sessions.
sample rates.
Resolves issue in PolyphaseChannelManager responding to sample rate
changes in the tuner. The manager now recreates the channelizer when
needed if the tuner's sample rate has changed since the last time the
channelizer was used.
Updates the Tuner selection view to reflect tuner lock state. Updates
the tuner editors to enable/disable frequency controller and sample
rate controls according to the tuner's lock state.