@@ -259,12 +259,14 @@ Compare that with this screenshot that shows the same computer and same airspy,
|
||||
|
||||

|
||||
|
||||
You can also use the airspy command line tools to diagnose if you are suffering from dropped samples in your airspy. In the following console screenshot, I'm using **airspy_rx** to test receiving and recording airspy samples at 10 MHz sample rate. In the first run, the airspy is plugged into a USB 3 hub that isn't able to deliver the full sample rate and it's dropping ~23,000 samples every second for an average of 9.9767 MSPS sample rate.
|
||||
You can also use the airspy command line tools to diagnose if you are suffering from dropped samples in your airspy.
|
||||
|
||||

|
||||
In the following console screenshot, I'm using **airspy_rx** to test receiving and recording airspy samples at 10 MHz sample rate. In the first run, the airspy is plugged into a USB 3 hub that isn't able to deliver the full sample rate and it's dropping ~23,000 samples every second for an average of 9.9767 MSPS sample rate.
|
||||
|
||||
In the second run, the airspy is plugged directly into a USB 3 port on the host computer (ie no hub) and it is able to deliver the full 10.0 MHz sample rate to the host computer.
|
||||
|
||||

|
||||
|
||||
**How do you fix this? **
|
||||
|
||||
* Try plugging your airspy into each of the USB ports on your host computer to see which port(s) can provide the full sample rate.
|
||||
|
||||